It is always important to pressure test prior to screeding. Ideally, pressure test using air, as this keeps the pipe free of the risk of frost damage, should a cold spell hit before the floor is warm.
If you do pressure test with water, the Robbens Systems® manifolds have the ability to isolate the pump set and keep it dry until it will be operated. This will prevent the risk of the pump sticking. |